WIS® 40-75
Product description
WIS® 40-75: AIR IN ITS PUREST FORM In some manufacturing applications, compressed air needs to be absolutely free of oil in order to comply with quality and purity requirements of specific industrial processes. Adding filters on an oil injected solution does not guarantee your system will be free of contamination in case of high oil load or filter failure. Only oil free compression technology can guarantee 100% oil free air production to satisfy these strict requirements. The WIS® 40-75 series is the best solution to satisfy these requirements with its patented water injection technology, the added benefit of superior drive efficiency, and a large choice of models. It complies with the most stringent standard for purity classes (ISO 8573-1 class 0) which insures no traces of oil can be found in the network even when using the “full-flow” measurement method.
Technical data air cooled
| Model | Pressure | FAD | Motor power | Noise level | Cooling air flow | outlet diameter | Weight |
|
| at ref. conditions |
|
| (compressed air) | Standard / with dryer |
| bar | m3/h | cfm | kW | hp | dB(A) | m3/h | " | kg |
|
|
|
|
|
|
|
|
|
| | WIS 40A | 7,5 | 306 | 180 | 30 | 40 | 68 | 11160 | 1,5 | 1226/1320 | | WIS 40B | 10 | 246 | 145 | | WIS 40C | 13 | 191 | 112 |
|
|
|
|
|
|
|
|
|
| | WIS 50A | 7,5 | 367 | 216 | 37 | 50 | 69 | 11160 | 1,5 | 1298/1395 | | WIS 50B | 10 | 311 | 183 | | WIS 50C | 13 | 249 | 147 |
|
|
|
|
|
|
|
|
|
| | WIS 60A | 7,5 | 437 | 257 | 45 | 60 | 71 | 15120 | 1,5 | 1321/1416 | | WIS 60B | 10 | 353 | 208 | | WIS 60C | 13 | 296 | 174 |
|
|
|
|
|
|
|
|
|
| | WIS 75A | 7,5 | 501 | 295 | 55 | 75 | 72 | 15120 | 1,5 | 1378/1497 | | WIS 75B | 10 | 425 | 250 | | WIS 75C | 13 | 354 | 208 |
Technical data water cooled
| Model | Pressure | FAD | Motor power | Noise level | Cooling water flow (DT=15°C) | outlet diameter | Weight |
|
| at ref. conditions |
| (compressed air) | Standard / with dryer |
| bar | m3/h | cfm | kW | hp | dB(A) | m3/h | " | kg |
|
|
|
|
|
|
|
|
|
| | WIS 40A | 7,5 | 319 | 188 | 30 | 40 | 65 | 2,16 | 1,5 | 1121/1215 | | WIS 40B | 10 | 256 | 151 | | WIS 40C | 13 | 198 | 117 |
|
|
|
|
|
|
|
|
|
| | WIS 50A | 7,5 | 386 | 227 | 37 | 50 | 66 | 2,7 | 1,5 | 1193/1290 | | WIS 50B | 10 | 328 | 193 | | WIS 50C | 13 | 262 | 154 |
|
|
|
|
|
|
|
|
|
| | WIS 60A | 7,5 | 463 | 272 | 45 | 60 | 67 | 3,3 | 1,5 | 1216/1313 | | WIS 60B | 10 | 389 | 229 | | WIS 60C | 13 | 324 | 190 |
|
|
|
|
|
|
|
|
|
| | WIS 75A | 7,5 | 550 | 324 | 55 | 75 | 68 | 4,02 | 1,5 | 1273/1392 | | WIS 75B | 10 | 472 | 278 | | WIS 75C | 13 | 392 | 231 |
Technical data WIS V
| Pressure | FAD at | Motor power | Noise level | Cooling air | Outlet diameter | Weight Standard / |
|
| ref. Conditions |
|
|
| flow | (compressed air) | with dryer (T) |
|
| min | max |
|
|
|
|
|
| | AIR COOLED | bar | m3/h | cfm | m3/h | cfm | kW | hp | db(A) | m3/h | " | kg |
|
|
|
|
|
|
|
|
|
|
|
| | WIS50V | 4 | 166 | 97 | 389 | 229 | 37 | 50 | 69 | 11160 | 1,5 | 1195/1306 | | 7 | 151 | 89 | 374 | 220 | | 9,5 | 184 | 108 | 320 | 189 | | 12,5 | 223 | 131 | 256 | 150 | | WIS75V | 4 | 164 | 96 | 577 | 339 | 55 | 75 | 72 | 15120 | 1,5 | 1195/1314 | | 7 | 152 | 90 | 558 | 328 | | 9,5 | 186 | 110 | 487 | 286 | | 12,5 | 218 | 128 | 393 | 231 |
|
|
|
|
|
|
|
|
|
|
|
|
| Pressure | FAD at | Motor power | Noise level | Cooling water | Outlet diameter | Weight Standard / |
|
| ref. Conditions |
|
|
| flow | (compressed air) | with dryer (T) |
|
| min | max |
|
|
| (DT = 15°C) |
|
| | WATER COOLED | bar | m3/h | cfm | m3/h | cfm | kW | hp | db(A) | m3/h | " | kg |
|
|
|
|
|
|
|
|
|
|
|
| | WIS50V | 4 | 162 | 95 | 400 | 235 | 37 | 50 | 66 | 2,7 | 1,5 | 1090/1201 | | 7 | 151 | 89 | 389 | 229 | | 9,5 | 187 | 110 | 331 | 195 | | 12,5 | 234 | 138 | 266 | 157 | | WIS75V | 4 | 162 | 96 | 588 | 346 | 55 | 75 | 68 | 4,02 | 1,5 | 1090/1209 | | 7 | 151 | 89 | 579 | 341 | | 9,5 | 187 | 110 | 512 | 301 | | 12,5 | 235 | 138 | 421 | 248 |
|
Product description Technical data air cooled Technical data water cooled Technical data WIS V Documents
|